What was found
FWD FUSELAGE AT BS 535 ABOVE S25L HAS ONE LIGHTNING STRIKE EXIT. DRILLED OUT DAMAGE IAW SRM 53-00-01. COMPLIED WITH HFEC INSPECTION IAW HDTM P 6, 51-00-16, NO CRACKS NOTED A 15270, APPLIED PRIMED IAW SRM 51-20-01, INSTALLED FASTENERS IAW SRM 51-40-02 AND 53-00-01, APPLIED TOP COAT AREA IAW AMM 51-21-00.