What was found
CORROSION ON FUEL ACCESS PLATE NR 1466C AT SETTLEMENT AREA AND COUNTERSINK HOLES IN REF CARD 41, ZONE 00, MRB 57-083-02, CORROSION ON COUNTERSINK HOLES ON SETTLEMENT AREA WERE REMOVED IAW SRM 51-22-2A. CONTERSINK HOLES WERE MEASURED AND, MAX DIAMETER ALLOWABLE IS .532" AND MAX DIAMETER MEASURED IS .558" IN (3) ADJACENT HOLES THEREFORE WAS FOUND OUT OF LIMITS IAW SRM 51-22-2A. FUEL ACCES PLATE 1466C WAS REPLACED AND WILL BE INSTALLED UNDER CARD 2800-0390, JOB 001- 0391.