What was found
CORROSION ON OTBD FWD AND AFT HOLES, RIB OF SLAT PANEL 1 STA XIS=83. CORROSION WAS REMOVED IN HOLE FWD AND AFTER SLAT TRACK, BUSHINGS WERE FABRICATED,TREATED AND INSTALLED IAW SRM 57-02, PAR 9 AND SRM 51-10-3, PAR 21 AND SRM 51-30-10, PAR 7 AND 8 FINAL ID DIAMETER 1.0655 FWD AND 1.060 AFT.