What was found
DURING INSPECTION, FOUND BROKEN FLOOR SUPPORT -Y254 BETWEEN FRAMES 24-28. PERFORMED PERMANENT REPAIR IAW SRM 53-00-14, PARA 4.G, FIGURE 207, SHEET 1 AND DWGS D53231346.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND BROKEN FLOOR SUPPORT -Y254 BETWEEN FRAMES 24-28. PERFORMED PERMANENT REPAIR IAW SRM 53-00-14, PARA 4.G, FIGURE 207, SHEET 1 AND DWGS D53231346.