What was found
CORROSION ON RIB HOLES OF SLAT PANEL 1 STA XIS=136 (LW). HOLES FWD WERE CLEANED IAW PS 900-1-2-1, NR 01 AND THEREFORE OUT OF LIMITS IAW SRM 57-02, PAR 9, TABLE 1, AND CORROSION ON HOLES AFT WERE REMOVED, BUSHINGS WERE FABRICATED, AND TREATED, AND INSTALLED IAW SRM 57-02, PAR 9 AND SRM 51-10-3 PAR 21, AND SRM 51-30-10 7 AND 8. FINAL ID Q0.935" AFT.