What was found
CORROSION ON RIB HOLES OF SLAT PANEL 1 STA XIS=136 (LW). HOLES FWD WERE CLEANED IAW PS 900-1-2-1, NR 01 AND THEREFORE OUT OF LIMITS IAW SRM 57-02, PAR 9, TABLE 1 AND CORROSION ON HOLES AFT WERE REMOVED, BUSHINGS WERE FABRICATED, AND TREATED , AND INSTALLED IAW SRM 57-02, PAR 9 AND SRM 51-10-3, PAR 21 AND SRM 51-30-10, 7 AND 8. FINAL ID: Q 0.935" AFT.