DURING INSPECTION, CORROSION ON PLATE LOCATED AT STRINGER 43L BETWEEN FRAMES 28- 29 IN FWD CARGO BAY. REPLACED PLATE IAW 51-72-11 AND DWG D53230861.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, CORROSION ON PLATE LOCATED AT STRINGER 43L BETWEEN FRAMES 28- 29 IN FWD CARGO BAY. REPLACED PLATE IAW 51-72-11 AND DWG D53230861.