What was found
DURING INSPECTION, FOUND CORROSION ON LOWER SILL AFT CABIN FLOOR STRUCT LOCATION AT FR 68 OUTER FLANGE LT SIDE MEASURED L=0.500", W=0.250" D=0.007" APPROXIMATELY PERFORMED PERMANENT REPAIR ON LOWER SILL AFT CABIN FLOUR STRUCT LOCATION AT FR68 OUTER FLANGE LT SIDE IAW SRM 53-41-14, PARAGRAPH 5.A, FIG 201.