What was found
CRACKED PAN ON RT FWD OVERWING EMERGENCY EXIT DOOR AT STOP FITTING NR 12, CARD 35 ZONE 201, INNER SKING, STOP FITTING AND CLIP WERE REMOVED CRACK WAS AS STOP DRILL DOUBLER WAS STOPPED, FABRICATED, TREATED, PAINTED, INSTALLED AND IDENTIFIED IAW SRM 51-30, 1, 51-30-2 51-30-5, 51-10-2, 51-01 51-10-3 PARA 14 AND 21 AND 52-05D FIG.51.