What was found
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT Y1292 BETWEEN FRAMES 64 - 66+5. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472000 .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT Y1292 BETWEEN FRAMES 64 - 66+5. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472000 .