What was found
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT Y1225 BETWEEN FRAMES 66+5 - 67+5. REPLACED FLOOR SUPPORT IAW SRM 51-7-11, DWG D53472000 .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT Y1225 BETWEEN FRAMES 66+5 - 67+5. REPLACED FLOOR SUPPORT IAW SRM 51-7-11, DWG D53472000 .