What was found
DURING INSPECTION, FOUND FLOOR SUPPORT BROKEN AT Y254 BETWEEN FRAMES 24-35. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53231181.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND FLOOR SUPPORT BROKEN AT Y254 BETWEEN FRAMES 24-35. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53231181.