What was found
DURING INSPECTION, FOUND CORROSION ON LOWER CORNER LOCATED FWD PASSENGER ENTRY DOOR RT AT FRAME 16, LEVEL STR23, INTERNAL STRUCTURE WITH MEASUREMENT OF L=0.500", W= 0.238" AND D=0.003" APPROXIMATELY, SSI 531163. REPLACED LOWER CORNER LOCATED FWD PASSENGER ENTRY DOOR RT AT FRAME 16, LEVEL STR 23 INTERNAL STRUCTURE IAW SRM 51-72-11 AND DWG NR D53112109.