What was found
CRACKED ANGLE BETWEEN AFT PAN AND NR 1 BEAM AT FWD R1 SERVICE DOOR. ANGLE WAS REMOVED, NEW FABRICATED, TREATED, PAINTED, AND INSTALLED IAW SRM 51-30-5, SRM 51-10-3, PAR 14 AND 21 DWG 9911579, REV L.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED ANGLE BETWEEN AFT PAN AND NR 1 BEAM AT FWD R1 SERVICE DOOR. ANGLE WAS REMOVED, NEW FABRICATED, TREATED, PAINTED, AND INSTALLED IAW SRM 51-30-5, SRM 51-10-3, PAR 14 AND 21 DWG 9911579, REV L.