What was found
WORN RIBS BS 1401 BETWEEN X=18 AND X=-18 AT VENTRAL STAIRWAY SHROUD. RIBS REPAIRED IAW SRM 53-01, FIG 2 AND DWG 9911998, REV D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WORN RIBS BS 1401 BETWEEN X=18 AND X=-18 AT VENTRAL STAIRWAY SHROUD. RIBS REPAIRED IAW SRM 53-01, FIG 2 AND DWG 9911998, REV D.