What was found
R1 OVERWING DOOR EMERGENCY EXIT MARKER FOUND INOPERATIVE DURING SERVICE CHECK. FOUND L2-788, LIGHT ASSY DISCONNECTED. CONNECTED THE LIGHT AND FOUND DIODE ASSY, R7-188, BAD. REPLACED THE DIODE ALONG WITH THE BATTERY AND POWER SUPPLY, CHECKED NORMAL.