What was found
CRACKED PAN INTERNAL STRUCTURE BS 637 AND BEAM NR MID CARGO DOOR. CRACKED PAN WAS STOPPED AND DRILLED IAW SRM 52-03, FIG 8, SH (1) TO (7), DOUBLER WAS FABRICATED IAW SRM 52-03, FIG 8 HEAT TREAT ON NEW DOUBLER AND AREA WERE TREATED AND PAINTED IAW SRM 51-10-3, PAR 21 AND 14. REPAIR DOUBLER WAS INSTALLED IAW SRM 51-30-2. SEAL RETAINER WAS INSTALLED IAW SRM 51-30-1.