What was found
CORROSION ON UPPER FLOOR SUPPORT BS 1212 BETWEEN LONGERONS 28-29R. FOUND OUT LIMITS AND WAS REPLACED IAW SRM 51-30-5, 51-10-3 P. 14-21-26, 51-10-4.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON UPPER FLOOR SUPPORT BS 1212 BETWEEN LONGERONS 28-29R. FOUND OUT LIMITS AND WAS REPLACED IAW SRM 51-30-5, 51-10-3 P. 14-21-26, 51-10-4.