What was found
FOUND STRINGER S25R DENTED BETWEEN BS 500B - 500C. MAINTENANCE REMOVED DAMAGE, AND PERFORMED HFEC INSPECTION IAW NDT MANUAL 51-00-00, FIG 23. NO DEFECTS NOTED. FABRICATED DOUBLER IAW SRM 53-00-03 REPAIR 1. INSTALLED DOUBLERS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND STRINGER S25R DENTED BETWEEN BS 500B - 500C. MAINTENANCE REMOVED DAMAGE, AND PERFORMED HFEC INSPECTION IAW NDT MANUAL 51-00-00, FIG 23. NO DEFECTS NOTED. FABRICATED DOUBLER IAW SRM 53-00-03 REPAIR 1. INSTALLED DOUBLERS.