What was found
CRACK ON SLANT SUPPORT OF BS 1136 BETWEEN LONGERONS 24-28. SUPPORT WAS REMOVED, ADJUSTED, DRILLED, TREATED, PAINTED AND INSTALLED IAW SRM 51-30-2, 51-10-3, PAR 14 AND 21 AND ERA 413029-14MA. AREA WAS APPLIED CIC IAW SRM 51-10-3, PAR 38.