What was found
ELONGATED HOLE ON SPLICE LOCATED Y1162 FRAME 66+5. LT SIDE LOWER POSITION INBD SIDE AT AFT GALLEY AREA. REPLACED SPLICE AND FASTENERS IAW SRM 51-72-11 AND DWG D53472000.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ELONGATED HOLE ON SPLICE LOCATED Y1162 FRAME 66+5. LT SIDE LOWER POSITION INBD SIDE AT AFT GALLEY AREA. REPLACED SPLICE AND FASTENERS IAW SRM 51-72-11 AND DWG D53472000.