What was found
DURING INSPECTION, FOUND A FLOOR SUPPORT CORRODED AT FRAME 68. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R THE FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND A FLOOR SUPPORT CORRODED AT FRAME 68. REMOVED CORROSION IAW SRM 51-74-00 AND FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. R & R THE FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.