What was found
DURING INSPECTION, A FLOOR SUPPORT BETWEEN FRAMES 66-68, Y1292 WAS FOUND CORRODED. BLENDED THE AREA IAW SRM 51-74-00 AND FOUND IT TO BE OUT OF LIMITS IAW TRM 53-41-15. INSTALLED A NEW FLOOR SUPPORT IAW SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, A FLOOR SUPPORT BETWEEN FRAMES 66-68, Y1292 WAS FOUND CORRODED. BLENDED THE AREA IAW SRM 51-74-00 AND FOUND IT TO BE OUT OF LIMITS IAW TRM 53-41-15. INSTALLED A NEW FLOOR SUPPORT IAW SRM 51-42-11.