What was found
DURING INSPECTION, UPPER INBD ATTACH ANGLE BETWEEN FLOORBEAMS AT FRAME 68 CORRODED. REMOVED CORROSION IAW SRM 51-74-00. REPLACED THE ATTACH ANGLE IAW SRM 51-42-11 & TRM 53-21-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, UPPER INBD ATTACH ANGLE BETWEEN FLOORBEAMS AT FRAME 68 CORRODED. REMOVED CORROSION IAW SRM 51-74-00. REPLACED THE ATTACH ANGLE IAW SRM 51-42-11 & TRM 53-21-01.