What was found
CORROSION ON INBD AND OTBD RIBS FWD/AFT BORES XOS 530.6 AT LT SLAT PANEL NR 5. AREAS WERE REWORKED AND FOUND OUT LIMITS IAW SRM 57-02, PAR 9 C(1) AND TABLE 1. BUSHINGS WERE FABRICATED IAW SRM 57-02, PAR 9 C 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON INBD AND OTBD RIBS FWD/AFT BORES XOS 530.6 AT LT SLAT PANEL NR 5. AREAS WERE REWORKED AND FOUND OUT LIMITS IAW SRM 57-02, PAR 9 C(1) AND TABLE 1. BUSHINGS WERE FABRICATED IAW SRM 57-02, PAR 9 C 2.