What was found
CORROSION ON FWD BORE OF INBD LUG OF OTBD FITTING STA XIS=186 AT SLAT 1 RT. AREAS WERE REWORKED AND MEASURED THEREFORE OUT LIMITS IAW SRM 57-02, PAR 9 C (1) TABLE 1 WITH DIAMETER 0.938". BUSHING WAS FABRICATED AND INSTALLED IAW SRM 57-02, PAR 9 C 2, LP1749542.