What was found
CORROSION ON UPPER BORES AND INBD FACES OF INBD/OTBD LUGS OF INBD FITTING XOS 196 AT SLAT 2 RT. AREAS WERE REWORKED AND FOUND OUT LIMITS IAW SRM 57-02, PAR 9 C (1). BUSHINGS FABRICATED IAW SRM 57-02, PAR 9 C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON UPPER BORES AND INBD FACES OF INBD/OTBD LUGS OF INBD FITTING XOS 196 AT SLAT 2 RT. AREAS WERE REWORKED AND FOUND OUT LIMITS IAW SRM 57-02, PAR 9 C (1). BUSHINGS FABRICATED IAW SRM 57-02, PAR 9 C.