What was found
ELONGATED HOLE ON CEILING SUPPORT BS 750-769 BETWEEN LONGERONS 4 - 5R. SUPPORT REPLACED IAW DW6 3353004, REV F, SRM 51-60-0, FIG 1, AND SRM 51-10-3, PAR 21 AND 14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ELONGATED HOLE ON CEILING SUPPORT BS 750-769 BETWEEN LONGERONS 4 - 5R. SUPPORT REPLACED IAW DW6 3353004, REV F, SRM 51-60-0, FIG 1, AND SRM 51-10-3, PAR 21 AND 14.