What was found
CORROSION FOUND ON FUEL ACCESS PANEL 1373C COUNTERSINK HOLES AND SETTLEMENT AREAS. CORROSION REMOVED IAW SRM 51-22-2A. FOUND OUT OF LIMITS IAW SRM 51-22-2A. NEW ACCESS PANEL INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON FUEL ACCESS PANEL 1373C COUNTERSINK HOLES AND SETTLEMENT AREAS. CORROSION REMOVED IAW SRM 51-22-2A. FOUND OUT OF LIMITS IAW SRM 51-22-2A. NEW ACCESS PANEL INSTALLED.