BS 1003 FRAME LBL 50 HAS TWO .2500" HOLES DRILLED WITHOUT APPROPRIATE SPACING. FABRICATED A STANDARD REPAIR IAW SRM 51-31-01 AND ERA 504723-14, REV O. (LP 1771814)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 1003 FRAME LBL 50 HAS TWO .2500" HOLES DRILLED WITHOUT APPROPRIATE SPACING. FABRICATED A STANDARD REPAIR IAW SRM 51-31-01 AND ERA 504723-14, REV O. (LP 1771814)