What was found
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT -Y1292 BETWEEN FRAMES 12 - 24 . REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53112812, D53110984.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT -Y1292 BETWEEN FRAMES 12 - 24 . REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53112812, D53110984.