What was found
CORROSION ON FLOOR SUPPORT X=8, BETWEEN BS 159 - 200. CORROSION AND FLOOR SUPPORT WERE REMOVED IAW SRM 51-10-3 PAR 26, 51-30-1 AREA WAS MEASURED IAW SRM 53-01, FIG. 1. NEW SUPPORT WAS DRILLED AND ADJUST IAW SRM 51-10-4. NEW SUPPORT WAS TREATED AND PAINTED IAW SRM 51-10-3, PAR 14, 21. NEW SUPPORT WAS INSTALLED IAW SRM 51-30-1. CIC WAS APPLIED IAW SRM 51-10-3, PAR 38.