What was found
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT BETWEEN Y1162 TO Y1292 AND FRAMES 66+5 - 67+17. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOOR SUPPORT BETWEEN Y1162 TO Y1292 AND FRAMES 66+5 - 67+17. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472780.