What was found
CORROSION ON BORE OF PLATES, ZRS=173 AND XH=5 LT SIDE LOCATED ON VERTICAL STAB REAR. BORE OF PLATES WAS REMOVED. HOLD WAS REWORKED WITH MEASURED HOLE LT OTBD: O 1.435 AND HOLE. LT INBD: O 1.435, THEREFORE WITHIN LIMIT. REPAIR AND BUSHING WAS FABRICATED, AREA WAS PAINTED, BUSHINGS WERE INSTALLED AND BORE PLATES WAS INSTALLED IAW SRM 55-02D FIG. 28. RII COMPLETED.