What was found
CRACK ON PAN BELOW STOP FITTING 4 BS 1155 IN AFT CARGO BAY. FASTENER WERE REMOVED IAW SRM 51-30-2. CRACK ON PAN WAS STOPPED DRILLED IAW SRM 52-05D, SHEET 1. REPAIR DOUBLER WAS FABRICATED IAW SRM 52-05D, SHEET 2, DOUBLER WAS PAINTED IAW SRM 51-10-3, PAR 14. REPAIR DOUBLER WAS INSTALLED IAW SRM 51-30-2.