What was found
CORROSION ON RT CUSP WEB BETWEEN X=-54 AND X=-60 AND Y=628 AND Y=655. CUSP WEB WAS REMOVED, FITTING WERE REMOVED, SPARS WERE REMOVED, NEW CUSP WEB WAS ADJUSTED AND DRILLED, NEW CUSP WEB WAS TREATED AND PAINTED, NEW CUSP WEB WAS INSTALLED, FITTINGS AND SPARS WERE INSTALLED IAW SRM 51-30-2, 51-30-1,51-30-5, 51-10-4,51-10-3, PAR 14 AND 21. Y=598, Y=617, Y=629, Y=636, Y=655,Y=674,Y=693,Y=701. MEASURE: NDT SPM 04-00-07 PAR 5, FIG 3, SHEET 1 AND 2 ORIGINAL THICK .020" REM .013IN ON ALL AREAS FROM STA 598 TO 701 IAW ER/A 511165-14 MA REV B. .