What was found
CRACK AND CORROSION ON RT CUSP WEB BETWEEN STA Y= 769 TO 788, FROM X =-54 TO X=-60 AT PAX CABIN FLOOR STRUCTURE. CORROSION WAS REMOVED IAW SRM 51-10-3 PAR 26. ORIGINAL THCKNESS IS 0.020" REMAINING IS 0.019" WITHIN LIMITS IAW ER/A 511165-14MA, REV B. AREA WAS TREATED AND PAINTED IAW SRM 51-10-3 PAR 14-21. CRACK WILL BE ATTENDED WITH CARD NR 250 ZONE 201.