What was found
CRACKED TEE FITTING BETWEEN BEAM 5 AND UPPER EDGE BS 654 AT MID CARGO DOOR. THE TEE FITTING WAS REMOVED IAW SRM 51-30-2, FORMER WAS FABRICATED IAW SRM 51-10-2 AND DWG 9957664, REV N, NEW FORMER WAS TREATED AND PAINTED IAW SRM 51-10-3, PAR 14 AND 21 NEW FORMER WAS INSTALLED IAW SRM 51-30-20 AND 51-30-01.