What was found
DURING INSPECTION, FOUND CORROSION ON THE FLOOR SUPPORT BETWEEN FRAMES 67 - 68 Y-765. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D534-72780, AND D53472816.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON THE FLOOR SUPPORT BETWEEN FRAMES 67 - 68 Y-765. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D534-72780, AND D53472816.