What was found
DURING INSPECTION, FOUND CORROSION ON SHEAR TIE OF FWD CARGO COMPARTMENT LOCATED FR 34 BETWEEN STR 41L TO STR 42L, SSI 532180. REPLACED SHEAR TIE AND FASTENERS OF FWD CARGO COMPARTMENT LOCATED FR 34 BETWEEN STR 41L TO STR 42L IAW SRM 51-72-11 AND DWG D53231712.