What was found
DURING INSPECTION, FOUND CORROSION ON SHEAR TIE OF FWD CARGO COMPARTMENT LOCATED FR 33 BETWEEN STR 40L TO STR 41L, SSI 532180. REPLACED SHEAR TIE LOCATED ON FWD C/C ON FR 33 BETWEEN STR 40L TO STR 41L IAW SRM 51-72-11 AND DWG D532 30338.