What was found
DURING INSPECTION, FOUND CORROSION ON SHEAR TIE OF FWD CARGO COMPARTMENT LOCATED FR 33 BETWEEN STR 41L TO STR 42L, SSI 532180. REPLACED SHEAR TIE LOCATED FWD C/C ON FR 33 BETWEEN STR 41L TO STR 42L IAW SRM 51-72-11 AND DWG D532 30338.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON SHEAR TIE OF FWD CARGO COMPARTMENT LOCATED FR 33 BETWEEN STR 41L TO STR 42L, SSI 532180. REPLACED SHEAR TIE LOCATED FWD C/C ON FR 33 BETWEEN STR 41L TO STR 42L IAW SRM 51-72-11 AND DWG D532 30338.