As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACKED ANGLE BELOW BEAM NR 1 AFT SECTION OF FWD SERVICE DOOR. THE ANGLE WAS REMOVED AND REPLACED IAW SRM 51-30-1 AND 51-30-5 PAR 7/8 CLIP WAS MANUFACTURED IAW DWG 9911579 REV L ANGLE WAS TREATED AND PAINTED IAW SRM 51-10-3. NEW ANGLE AFT WAS INSTALLED IAW SRM 51-30-1 AND 51-30-5.