What was found
DURING INSPECTION, FOUND CORROSION ON LOWER SILL LOCATED BETWEEN FR 66 TO FR 68 AT LEVEL STR 23L AFT PAX CABIN. MEASURES L: 1.500", W: 1.250", D: 0.006", APPROXIMATELY, SSI 534147. REPLACED LOWER SILL LOCATED BETWEEN FR 66 TO FR 68 AT LEVEL STR 23L AFT PAX CABIN IAW SRM 51-72-11 AND DWG D53470150, D53480505.