What was found
LIGHTNING STRIKE STATIC PORT, CAPTAIN ON LOWER FUSELAGE ON FRAME 23+13" BETWEEN STRINGER 31L TO STRINGER 33L, PERFORMED TEMPORARY REPAIR ON STATIC PORT CAPTAIN ON LOWER FUSELAGE ON FRAME 23 + 13" BETWEEN STRINGER 31L TO STRINGER 33L AND PERFORMED REWORK ON LIGHTNING STRIKE DAMAGE TO 9 HOLES, AREA IAW SRM 51-73-00, PERFORMED DVI ON REWORKED AREA IAW NTM 51-90-00 TO ENSURE NOT ADDITIONAL DAMAGE EXIST AND PERFORMED HFEC INSPECTION ON REWORKED AREA IAW NTM 51-10-08 TO ENSURE NOT CRACK FREE CONDITION IAW ER/A NR 531906-14, REV .1 AND REV ORIGINAL SECTION 1, 9 HOLES AREAS REPAIR.