What was found
DURING INSPECTION, FOUND CORROSION ON FLOORBEAM FRAME 20 AND -Y254. REPLACED THE FLOORBEAM IAW SRM 51-72-11, DWG D53112819, PRI 532202-14, REV O AND ER/A 532202-14.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON FLOORBEAM FRAME 20 AND -Y254. REPLACED THE FLOORBEAM IAW SRM 51-72-11, DWG D53112819, PRI 532202-14, REV O AND ER/A 532202-14.