What was found
CORROSION ON INTERNAL DOUBLER, CUT OUT, AT ELEVATOR ACCUMULATOR ACCESS DOOR. DAMAGED CUTOUT WAS REMOVED IAW SRM 51-30-2 AND 51-30-5. NEW CUT OUT WAS FABRICATED IAW DWG 5917686, REV AA. NEW CUTOUT WAS INSTALLED IAW SRM 51-30-2 AND 51-30-5.