What was found
CORROSION AND CRACKS ON RT WING LOWER ACCESS CUTOUT BETWEEN XRS=189.0-214.0 AND STRINGERS 12-15-RT. BOLT HOLE WAS REMOVED IAW SRM 51-22-2A, BUSHING WAS FABRICATED AND INSTALLED IAW SRM 51-22-2A, PAR 7B 2, 51-10-3 PAR 21, 51-30-10 AND 51-10-4.