What was found
CRACKED ANGLE ON UPPER CHANNEL BELOW STOP FITTING NR 12 AT RT/ FWD EMERGENCY EXIT. NEW ANGLE WAS FABRICATED IAW SRM 51-10-2 AND DWG 9957735, REV 6, SRM 51-10-3 PAR 14/21. ANGLE WAS INSTALLED IAW SRM 51-30-2 AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED ANGLE ON UPPER CHANNEL BELOW STOP FITTING NR 12 AT RT/ FWD EMERGENCY EXIT. NEW ANGLE WAS FABRICATED IAW SRM 51-10-2 AND DWG 9957735, REV 6, SRM 51-10-3 PAR 14/21. ANGLE WAS INSTALLED IAW SRM 51-30-2 AND 51-30-5.