What was found
DURING INSPECTION, FOUND CORROSION ON THE FLOOR SUPPORT AT Y-1732 BETWEEN FRAMES 65 - 66. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG NR D53470150.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON THE FLOOR SUPPORT AT Y-1732 BETWEEN FRAMES 65 - 66. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG NR D53470150.